MechanicalandEnvironmentalSpecifications
NOTE:Allspecificationsinthismanualaresubjecttochange.
Table 1. General Specifications
ITEM DESCRIPTION
UsageEnvironment Controlledindoorenvironment
PlugTestAdapterLength(w/standardcables) 246mm+/‐2mm(9.70inches+/‐.08inches)(Characteristic)
ReceptacleTestAdapterLength(w/std.cables) 381mm+/‐2mm(15.00inches+/‐.08inches)(Characteristic)
OperatingTemperature 0°Cto+55°C(32°Fto+131°F)(Characteristic)
StorageTemperature‐40°Cto+70°C(‐40°Fto+158°F)(Characteristic)
8639‐TPA‐RCablePinout
The8639‐TPA‐Rcablesprovide28SMAconnectors(accessuptosixlanesofdifferentialTX
andRX,anduptotwodifferentialreferenceclocks),one4‐positionpowerconnector,andone
16‐positionalternateconnector.Labelsclearlymarkeachcableorconnector.The
following
figurereferstopin‐descriptiontablesforeachofthethreeconnectortypes.Note:Thepower
supplieseachhave22µFinparallelwitha0.01µFcapacitor,withtheexceptionofthe+3.3V,
whichdoesnothavethe22µFcap.Theprechargesignalseachhaveaseries2
ohmresistorto
theirrespectivepowersupplies.